Beijing Jinwei Kangda Instruction for Fiberglass Splint
Product Name:Fiberglass Splint
Description:
Fiberglass splint consists of upper and lower side non-woven fabric and a middle board made with
a knitted fiberglass fabric impregnated with a water-activated polyurethane resin.It has the charac-teristics of suitable strength, fast curing and easy operation and so on.t is mainly used for external fixation such as fractures or soft tissue injuriesApplication MeA. Choose the appropriate size according to the injured partB. After opening the package (the long roll splint is cut off the appropriate length as required, andthe cut end of the bag is immediately sealed with a special clip), soak the splint into 20-30°C waterfor about 5-10 seconds, and squeeze it for 2-3 seconds at the same time to make it fully soakedC. Squeeze out or use a dry towel to remove excess water after taking it outD. Put the thickness side of splint pad on the part to be fixed and wrap and fix it with a gauzebandage or elastic bandage. The tightness of the bandage should be moderate, if too tight ,it willaffect the blood circulation of the affected part, if too loose ,it will affect the fixation effect.E. Shaping it to ensure that the splint fits with the limb closely.F. The operation is generally completed within 3 minutes, the curing will start in 3-5 minutes, andit can be achieved the functional strength in 20 minutes. Before the product is completely
solidified, the injured part of the patient should not move freelyG. The splint can be removed by cutting or loosening the gauze bandage or elastic bandage.Cautions:OIt should be used immediately after opening the bag. After the long rolled splint is cut off anappropriate length as required, immediately seal the cut end of the bag with a special clip toprevent the splint from gradually hardening with the aOThe soaking time of the splint in water and the temperature of the water directly affect the curingtime, and the doctor can adjust it as needed.OCheck packing if have any damage or holes, If the product is partially hardened, it can't be used.OThe application of the splint must be under the operation or direction of the qualified doctorStorage conditions: The splint should be stored in a cool and dry place and the carton should beinverted to place every half year. When place an order or transport, it is recommended to order ortransport each carton with splint fully to avoid carton with extra room is easy to be broken andLead to splint bag air leakage or splint solidificationProduction date, expiry date: Production date refers to product pouch and it should be used inAfter Sales Service Commitment: if the splint is hardened due to quality problems, it can be
the period of validity, The shelf life is three years
replaced of the same size by local distributors.
Beijing Jinwei Kangda Medical Instrument Ltd
Add:Room 1406-1409,1st Building,No, 14 Courtyard,South Road of Western 3rd Ring-Road,
Fengtai District,Beijing 100073International Department
销售QQ号:46233604